Backup power supply Avansa 700 W
Code: AVANSA 700WProduct detailed description
- for circulation pumps, without battery
!!! WARNING !!!
|
- maximum capacity : 1000 VA
- maximum rated power : 700 W
- main input power : 150 – 270 VAC
- input frequency : 45 – 65 Hz
- output power : 207 – 241 VAC
- input frequency : 50 – 60 Hz
- switching time : <4ms
- overload protection :110% 130% (30 seconds)
- consumption in idle mode : 22W
- dimensions (H/W/D) : 18,5x14,5x34 cm
- the backup power supply is suitable for devices with a maximum power of approximately 350 W in total
|
||||||||||||||||
This product belongs to the group of professional automatic backup power supplies (UPS) specifically designed and manufactured for uninterrupted power supply of solid fuel boilers in the event of a power failure. In the event of a power failure, the backup power supply (UPS) provides immediate energy from the battery, so that the circulation pump remains running and the boiler is safely cooled.
Main features :
- The backup power supply (UPS) stops in the case of a discharged battery. If the battery is discharged to 10.8V, the backup power supply disconnects the power supply to prevent battery damage. A fast audio alarm signals: - Overload protection: In the case that the load of the backup power supply (UPS) exceeds 110% of the rated power, the backup power supply (UPS) stops to prevent damage.
- Short-circuit protection: The backup power supply (UPS) stops in the case of a short circuit. – Voltage regulator (AVR) ensures constant voltage for devices within the given range. Battery activation: the system switches to the battery and provides uninterrupted power supply for the device. – Bypass function:
- Automation: if the power supply in the grid is non-standard, the backup power supply automatically switches to the battery. – Conversion for starting tasks: in some cases, a higher starting power is required than the rated power of the backup power supply (UPS). In this case, the backup power supply (UPS) solves this problem by delivering 110% of its capacity. After delivering the capacity, it turns off.
- High charging current: the initial charging current is about 10A. Charges the battery in a shorter time than standard chargers.
- Preservation of the battery in standby mode: after the battery is fully charged, the backup power supply (UPS) keeps the battery charged. To achieve optimal results, the battery must have a capacity within the range of values: 40 Ah -190 Ah. Do not use a battery with a capacity less than 40Ah, as the initial charging current of the backup power supply (UPS) (up to 10A) may reduce its lifespan.
Additional parameters
| Category: | Backup power supplies, batteries, detectors |
|---|---|
| Warranty: | 2 years |
| Weight: | 6.5 kg |