Backup power supply Avansa 500 W
Code: AVANSA 500WProduct detailed description
- for circulation pumps, without battery
!!! WARNING !!!
|
- maximum capacity: 800 VA
- maximum rated power: 500W
- main input power: 150 – 270 VAC
- input frequency: 45 – 65 Hz
- output power: 207 – 241 VAC
- input frequency: 50 – 60 Hz
- switching time: <4ms
- overload protection: 110% 130% (30 seconds)
- consumption in idle mode: 22W
- dimensions (H/W/D): 18.5x14.5x34 cm
- the backup power supply is suitable for devices with a maximum total power of approximately 250 W
|
||||||||||||||||
This product belongs to the group of professional automatic backup power supplies (UPS) specifically designed and manufactured for uninterrupted power supply of solid fuel boilers in the event of a power failure. In the event of a power failure, the backup power supply (UPS) provides immediate energy from the battery, so the circulation pump remains running and the boiler cools down safely.
Main features:
- The backup power supply (UPS) stops in the case of a discharged battery. If the battery is discharged to 10.8V, the backup power supply disconnects the power supply to prevent battery damage. A rapid audio alarm signals: - Overload protection: In the event that the load on the backup power supply (UPS) exceeds 110% of the rated power, the backup power supply (UPS) stops to prevent damage.
- Short circuit protection: The backup power supply (UPS) stops in the case of a short circuit. – Voltage regulator (AVR) ensures constant voltage for devices within the given range. Battery activation: the system switches to the battery and provides uninterrupted power supply for the device. – Bypass function:
- Automation: if the power supply in the grid is non-standard, the backup power supply automatically switches to the battery. – Conversion for starting tasks: in some cases, a higher starting power is required than the rated power of the backup power supply (UPS). In this case, the backup power supply (UPS) solves this problem by supplying 110% of its capacity. After delivering the capacity, it turns off.
- High charging current: the initial charging current is approximately 10A. It charges the battery in a shorter time than standard chargers.
- Preservation of the battery in standby mode: after the battery is fully charged, the backup power supply (UPS) keeps the battery charged. To achieve optimal results, the battery must have a capacity within the range of 40 Ah -190 Ah. Do not use a battery with a capacity less than 40 Ah, as the initial charging current of the backup power supply (UPS) (up to 10A) may reduce the battery life.