DELTASTAV.EU | Online wholesale

Backup power supply Avansa 500 W + battery 46 Ah

Code: AVANSA SET DELTA
Sale Wholesale discount Wholesale discount 2
Not rated Rating details
–30 %
zalozny zdroj avansa 500 w original
401,03 € –30 % 280,72 € / pcs 228,23 € excl. VAT Measure price:
In stock

- for circulation pumps, preferred SET with battery

Detailed information

Product detailed description

- for circulation pumps, SET with advantage - Avansa 500 W + AKUMA Vortek 12V 46Ah 450A 
Standby power supply: 
Technical specifications:
  • maximum capacity: 800 VA
  • maximum rated power: 500W
  • main input power supply: 150 – 270 VAC
  • input frequency: 45 – 65 Hz
  • output power: 207 – 241 VAC
  • input frequency: 50 – 60 Hz
  • switching time: <4ms
  • overload protection: 110% 130% (30 seconds)
  • consumption in idle mode: 22W
  • dimensions (H/W/D): 18.5x14.5x34 cm
  • maximum battery capacity connected: 120 Ah
  • the backup power supply is suitable for devices with a maximum power of approximately 250 W in total
Estimated performance time of the backup power supply according to battery type and consumption [W]:

100W

200W

300W

 46Ah battery

3.83 h

2.09 h

1.44 h  

This product belongs to the group of professional automatic backup power supplies (UPS) specially designed and manufactured for uninterrupted power supply of solid fuel boilers in the event of a power outage. In the event of a power failure, the backup power supply (UPS) provides immediate energy from the battery, so that the circulation pump remains in operation and the boiler cools down safely.
Main features:
  • The backup power supply (UPS) stops in the case of a discharged battery. If the battery is discharged to a value of 10.8V, the backup power supply disconnects the power supply to prevent battery damage. A quick audio alarm signals: - Overload protection: In the event that the load on the backup power supply (UPS) exceeds 110% of the rated power, the backup power supply (UPS) stops to prevent damage.
  • Short circuit protection: The backup power supply (UPS) stops in the case of a short circuit. – Voltage regulator (AVR) ensures constant voltage for devices within the given range. Battery activation: the system switches to the battery and provides uninterrupted power supply for the device. – Bypass function:
  • Automation: if the power supply in the grid is non-standard, the backup power supply automatically switches to the battery. – Conversion for starting tasks: in some cases, a higher starting power is required than the rated power of the backup power supply (UPS). In this case, the backup power supply (UPS) solves this problem by supplying 110% of its capacity. After delivering the capacity, it turns off.
  • High charging current: the initial charging current is about 10A. Charges the battery in a shorter time than standard chargers.
  • Maintaining the battery in standby mode: after the battery is fully charged, the backup power supply (UPS) keeps the battery charged. To achieve optimal results, the battery must have a capacity within the range of values: 40 Ah -190 Ah. Do not use a battery with a capacity less than 40Ah, as the initial charging current of the backup power supply (UPS) (up to 10A) may reduce its lifespan.
 
Battery:  

Features: 
  • low-maintenance automotive battery
  • lead / calcium technology
  • state monitoring using a "magic eye"
  • increased starting current
  • improved lid with central venting system
  • low self-discharge
  • higher corrosion resistance
 
Technical parameters: 
  • capacity: 46 Ah
  • discharge current at -18°C: 450 A
  • terminal type: 1
  • cell arrangement: 0
  • dimensions (l x w x h): 207 x 175 x 175 mm
  • mounting: B13 / B15

 

Additional parameters

Category: Backup power supplies, batteries, detectors
Warranty: 2 years
Weight: 21 kg

Product rating

Be the first who will post an article to this item!

Do not fill out this field

How would you rate this product? Choose 1 to 5 stars, where 1 is the worst and 5 is the best rating.

By submitting a review, you agree to the privacy policy

Discussion

Do not fill out this field

Security check

By posting a comment, you agree to the privacy policy

List of discussions

R Avatar of author 07.01.2023 11:29
Dobrý deň ,viete mi povedať prečo tento záložný zdroj mení polaritu na výstupe? vprípade ak je zdroj napajaný zo siete tak na výstupnej zásuvke je plus hore a v prípade výpadku ele.siete začne dodávať elektrinu z baterie a vtedy už je plus dole. Takto fungujúci záložný zdroj mi kurenáry odmietli zapojiť , pre samotné obehové čerpadlo to nieje problém že mení polaritu ale ja tam mám napojené aj niejaké obehové čerpadlo na Tepelnom čerpadle cez jeho matičnú dosku ktorá by sa mohla odpáliť pri zmene polarity, čo stým ? ďakujem
E Avatar of author 14.01.2023 10:01
Priateľu,nepochopil som ,o akej polarite na výstupe meniča hovoríš.
Vytvořil Shoptet | Design Shoptak.cz.