Backup power supply Avansa 1050 W
Code: AVANSA 1050WProduct detailed description
- for circulation pumps, without battery
| !!! WARNING !!! The backup power supply AVANSA 1050 W requires a battery voltage of 24 V, therefore it is necessary to connect 2 batteries in series with a voltage of 12 V, each of which has a maximum capacity of 120 Ah |
Technical specifications:
- maximum capacity: 1500 VA
- maximum rated power: 1050 W
- main input power: 150 – 270 VAC
- input frequency: 45 – 65 Hz
- output power: 207 – 241 VAC
- input frequency: 50 – 60 Hz
- switching time: <4ms
- battery capacity: 12V DC
- overload protection: 110% 130% (30 seconds)
- consumption in idle mode: 22W
- dimensions (H/W/D): 18.5x14.5x34 cm
- the backup power supply is suitable for devices with a maximum power of approx. 500 W in total
|
||||||||||||||||
This product belongs to the group of professional automatic backup power supplies (UPS) specially designed and manufactured for uninterrupted power supply of solid fuel boilers in the event of a power failure. In the event of a power failure, the backup power supply (UPS) provides immediate energy from the battery, so that the circulation pump remains running and the boiler is safely cooled.
Main features:
- The backup power supply (UPS) stops in the case of a discharged battery. If the battery is discharged to a value of 10.8V, the backup power supply disconnects the power supply to prevent battery damage. A rapid sound alarm signals: - Overload protection: In the case that the load of the backup power supply (UPS) exceeds 110% of the rated power, the backup power supply (UPS) stops to prevent damage.
- Short-circuit protection: The backup power supply (UPS) stops in the case of a short circuit. – Voltage regulator (AVR) ensures constant voltage for devices within the given range. Battery activation: the system switches to the battery and provides uninterrupted power supply for the device. – Bypass function:
- Automation: if the power supply in the grid is non-standard, the backup power supply automatically switches to the battery. – Conversion for task start-up: in some cases, a higher starting power is required than the rated power of the backup power supply (UPS). In this case, the backup power supply (UPS) solves this problem by supplying 110% of its capacity. After delivering the capacity, it turns off.
- High charging current: the initial charging current is about 10A. Charges the battery in a shorter time than standard chargers.
- Keeping the battery in standby mode: after the battery is fully charged, the backup power supply (UPS) keeps the battery charged. To achieve optimal results, the battery must have a capacity in the range of values: 40 Ah -190 Ah. Do not use a battery with a capacity less than 40Ah, as the initial charging current of the backup power supply (UPS) (up to 10A) may reduce the battery life.
Additional parameters
| Category: | Backup power supplies, batteries, detectors |
|---|---|
| Warranty: | 2 years |
| Weight: | 6.5 kg |
Product rating
Be the first who will post an article to this item!
Discussion
List of discussions
M
Martin
Dobrý deň, potrebujem zaistiť obehové čerpadlo UK s príkonom 93W,230V. A to na čas 8 hodín. Podla info na vašej stránke som nenašiel vhodný založný zdroj pre toto čerpadlo s týmito podmienkami.Ako by ste tento problém riešili? Poradte mi. Martin, Stropkov
D
Deltastav
Dobrý deň,
aby kapacita vydržala 8 hodín, teoreticky potrebujete zapojiť do kaskády ku danému zdroju ešte jednu batériu 55Ah - ak rátame pri 100W. Bohužiaľ prakticky akým spôsobom je to možné, Vám neviem poradiť, to už by zrejme bolo na elektrikára.
Príjemný deň.