AVANSA 110 Z - thermostat for circulation pump and DHW
Code: AVANSA 110ZProduct detailed description
Thermostat AVANSA 110 - Z.
It is designed to control the heating pump and the DHW tank pump. The heating pump switches on when the boiler temperature exceeds the switch-on temperature set by the user. The DHW tank pump operates on the basis of the temperature difference: it switches on when the boiler temperature exceeds the tank temperature by the set hysteresis and runs until the boiler and tank temperatures equalise or until the set tank temperature is reached.
Function P (priority) – when this function is active, the DHW tank pump has priority. The DHW tank pump switches on first and the heating pump starts only after the set tank temperature has been reached. When this function is switched off, the pumps operate independently, without priority for the DHW tank pump. To activate the priority function, press and hold the MENU button until the letter P appears on the display, then use the arrows to select ON (activate) or OFF (deactivate).
Function L (summer mode) – switches off the heating pump so that only the DHW tank pump operates. The heating pump switches on only if the boiler temperature exceeds 90°C, to protect the boiler against overheating.
Technical data:
- supply voltage: 230V 50Hz ±10%
- ambient temperature: -10...+50°C
- switching current: 6A
- temperature measurement range: 0...90°C
- temperature setting range: heating 5...80°C, DHW 20...80°C
- adjustable tank hysteresis: 10...30°C
- maximum sensor temperature: -10...120°C
Additional parameters
| Category: | controllers for pumps and boiler rooms |
|---|---|
| Warranty: | 2 years |
| Weight: | 0.8 kg |
Product rating
Be the first who will post an article to this item!
Discussion
List of discussions
MI
Martina Ihnatkova
Dobry den. Dnes rano mi termostat piskal. Viete mi poradit prečo? Dalujem za odpoveď.